Designing AC Circuits: Filters, Transformers, and Power Factor

Understanding AC Circuit Basics: Voltage, Current, and PhaseAlternating current (AC) is the form of electrical power most commonly used in homes, businesses, and industry. Unlike direct current (DC), which flows in one direction, AC periodically reverses direction, producing sinusoidal waveforms that vary with time. This article covers the fundamental concepts of AC circuits — voltage, current, phase — and explains how they interact through elements like resistors, inductors, and capacitors. It also touches on impedance, power in AC circuits, resonance, and practical considerations for measurement and safety.


1. What is AC voltage?

AC voltage is an electrical potential difference that varies periodically with time. The most common waveform is sinusoidal, described by:

V(t) = V_peak · sin(ωt + φ)

where:

  • V(t) is instantaneous voltage,
  • V_peak is the peak (maximum) voltage,
  • ω = 2πf is the angular frequency (f is frequency in Hz),
  • φ is the phase angle.

Two commonly used amplitudes:

  • Peak voltage (V_peak): maximum value of the waveform.
  • Root mean square (RMS) voltage: the effective DC-equivalent value useful for power calculations. For a sine wave:

V_RMS = V_peak / √2

Example: In many countries, mains voltage is specified as 230 V RMS at 50 Hz (Europe) or 120 V RMS at 60 Hz (North America).


2. What is AC current?

AC current describes the flow of charge that alternates direction. The instantaneous current is:

I(t) = I_peak · sin(ωt + θ)

where I_peak is peak current and θ is the current phase angle. Like voltage, current is often expressed in RMS:

I_RMS = I_peak / √2

The relationship between voltage and current depends on circuit elements; they may be in phase or phase-shifted relative to each other.


3. Phase and phase difference

Phase refers to the relative shift between two sinusoidal waveforms of the same frequency. If voltage leads current by φ degrees, we say voltage is φ ahead of current. Phase differences arise from reactive elements:

  • In purely resistive circuits, voltage and current are in phase (φ = 0°).
  • In inductive circuits, current lags voltage by 90° for an ideal inductor.
  • In capacitive circuits, current leads voltage by 90° for an ideal capacitor.

Phase is crucial because it affects real power transfer and how elements combine in AC circuits.


4. Circuit elements: R, L, C

Resistor ®

  • Voltage and current are proportional and in phase: V(t) = R · I(t).
  • Impedance Z_R = R (purely real).

Inductor (L)

  • Voltage leads current. Instantaneous: v(t) = L · di/dt.
  • Reactance X_L = ωL.
  • Impedance Z_L = jωL (purely imaginary, positive).

Capacitor ©

  • Current leads voltage. Instantaneous: i(t) = C · dv/dt.
  • Reactance X_C = 1 / (ωC).
  • Impedance Z_C = 1 / (jωC) = -j / (ωC) (purely imaginary, negative).

Here j denotes the imaginary unit (used in engineering, j^2 = -1).


5. Impedance and phasors

Impedance (Z) generalizes resistance to AC, combining R and reactance X (from L and C):

Z = R + jX

Use complex numbers or phasors to represent sinusoids as vectors in the complex plane. A phasor transforms v(t) = V_peak·sin(ωt+φ) into Ṽ = V_RMS∠φ (or V_peak∠φ depending on convention). Phasor algebra turns differential equations into algebraic equations:

Ṽ = Ĩ · Z

This simplifies circuit analysis for steady-state sinusoidal signals.


6. Power in AC circuits

There are three useful power quantities:

  • Real (active) power P (watts): P = V_RMS · I_RMS · cosφ = VI cosφ. This is the average power actually consumed or delivered.
  • Reactive power Q (volt-amperes reactive, VAR): Q = V_RMS · I_RMS · sinφ. This represents energy alternately stored and released by reactive components.
  • Apparent power S (volt-amperes, VA): S = V_RMS · I_RMS. Relates to the magnitude of complex power S̃ = P + jQ.

Power factor = cosφ = P / S. Improving power factor reduces wasted current for the same real power.


7. Series and parallel AC circuits

Series circuits: current is the same through all elements; voltages add vectorially (phasor sum). Total impedance Z_total = Z1 + Z2 + …

Parallel circuits: voltage is same across all branches; currents add vectorially. Admittance Y = 1 / Z; total admittance is sum of branch admittances.

Example: Series R and XL: Z = R + jX_L I = V / Z Voltage drop across each element = I · Z_element (phasor).


8. Resonance

In RLC circuits, resonance occurs when inductive and capacitive reactances cancel: X_L = X_C → ω_0 = 1/√(LC). At resonance in a series RLC, impedance is minimum (equal to R), current is maximum, and voltage/current are in phase. In parallel resonance, impedance is maximum.

Resonance is used in filters, tuners, and oscillators.


9. Measurement and instruments

  • Oscilloscope: visualizes instantaneous waveforms, shows phase differences directly.
  • True-RMS multimeter: measures RMS values accurately even for non-sinusoidal waves.
  • Power meter / wattmeter: measures real, reactive, and apparent power.
  • LCR meter: measures inductance, capacitance, and resistance.

When measuring phase, use dual-channel oscilloscope and compare zero crossings or measure time shift Δt; φ = ωΔt = 2πfΔt.


10. Practical considerations

  • Line impedance and distributed effects matter at high frequencies; use transmission-line theory when wavelength ≈ circuit length.
  • Non-ideal components have parasitic resistance and capacitance; model them when precision matters.
  • Safety: always de-energize circuits before working, use proper PPE, and follow local electrical codes.

11. Simple examples

  1. Series R-L circuit: V = 120∠0° V, R = 10 Ω, L = 0.03 H, f = 60 Hz. ω = 2π·60 = 377 rad/s; X_L = ωL = 11.31 Ω. Z = 10 + j11.31; |Z| = √(10^2 + 11.31^2) = 15.09 Ω. I = V / Z = 120∠0° / 15.09∠48.6° = 7.95∠-48.6° A (current lags voltage).

  2. Series R-C circuit at 50 Hz: R = 50 Ω, C = 1 μF, V = 230 V RMS. ω = 2π·50 = 314.16; X_C = 1/(ωC) = 1/(314.16·1e-6) = 3183 Ω. Z ≈ 50 – j3183; current small and leads voltage slightly.


12. Summary (key takeaways)

  • AC alternates direction; mains are typically 50 or 60 Hz.
  • RMS values give DC-equivalent amplitudes for power calculations.
  • Phase difference between voltage and current matters for power and circuit behavior.
  • Use phasors and impedance to simplify steady-state AC analysis.